flowspek ag
HPLC - UV/VIS Spectroscopy 
Fiber Optic and Diode Array Applications 
Software - Fluorescence 
 HPLC Detector K-2600
Overview Specifications Ordering Information Print Version Documentation
Overview
 
Return to HPLC Overview
K-2600The K-2600 Spectrophotometer is a programmable rapid scanning detector for HPLC and can record multiple chromatograms at different wavelengths.
 
Acquire Data at Different Wavelengths
Multiple chromatograms can be simultaneously acquired at different wavelengths. In the »stand-alone« mode the detector offers two adjustable wavelengths per run, while four wavelengths are available if externally controlled.
 
GLP Functions
The K-2600 Detector provides GLP functions such as: detailed reports, displaying the total hours of lamp operation, total number of lamp ignitions, and more.
 
Fiber-Optic Options
The use of fiber-optic guides permits the spacial separation of the K-2600 Detector and flow cell, which makes operation with externally thermostatted cells or in hazardous areas possible. Fiber-optic guides are available in standard or customised lengths.
 
Large Selection of Flow Cells
A large range of flow cells, from nano-HPLC cells for flowrates above 100 nL/minute to preparative cells for flowrates up to 10000 ml/minute, offers maximum flexibility and permits use of the K-2600 Detector for practically all HPLC applications.
 
Compact
The small footprint allows the K-2600 Detector to be installed practically anywhere.
 
Easily Integrated into Systems
The K-2600 Detector is of modular design, easy-to-use and easy-to-maintain, which allows it to be integrated easily into existing systems as a module.
SpecificationsTop
Wavelength range190 - 740 nm, 2nd order cut-off filter at 370 nm
Light sourceDeuterium lamp as standard, optional Tungsten-Halogen lamp
Bandwidth8 nm
Wavelength accuracy±1 nm
Measuring range0 – 4 AU
Baseline drift < 1 x 10-4 AU/h at 240 nm, t = 1 sec.
Noise< 1 x 10-5 AU at 240 nm, t = 1 sec.
Scan function Whole wavelength range with flow in approx. 100 nm/sec.
Integrator output±0.1 V / ±1 V / ±10 V adjustable in 16 ranges
Data acquisitionAnalogue via Integrator output
DisplayLCD, 2 x 24 characters
Time constant0.1 – 10 Seconds adjustable in 7 ranges
Remote Control2 RS-232 interfaces, analogue inputs for error and / or program start, Outputs (TTL, Relay remote connections) for event, error and / or start, fraction collection function, Analogue control capability for wavelength and autozero
(The pump can be controlled via Geminyx Software.)
GLPRecording of total running time and number of lamp ignitions.
FeaturesAddition of an electric switching valve allows use of solvent recycling or fraction collection. Storage of up to 20 programs possible.
Dimensions160 x 185 x 340 mm (W x H x D)
Weight5.5 kg
All specifications may be subject to change for technical reasons.
Ordering InformationTop
A4070WellChrom rapid scanning Spectralphotometer K-2600 without flow cell, with accessories for operation without fiber-optics
A4090WellChrom rapid scanning Spectralphotometer K-2600 without flow cell, with accessories for operation with fiber-optics
Analytical Flow Cells
A406110 mm path, 1/16’’ connections, 10 µL, stainless steel, max. flow 20, max. pressure 300 bar
A40423 mm path, 1/16’’ connections, 2 µL, stainless steel, max. flow 50, max. pressure 300 bar
A40453 mm path, 1/16’’ connections, 2 µL, PEEK, max. flow 50, max. pressure 30 bar
Preparative Flow Cells
A40660.5 / 1.25 / 2 mm path, 1/8’’ connections, stainless steel, max. flow 1000, max. pressure 200 bar(Cell volumes for adjustable cells are: 0.50 mm = 1.7 µL; 1.25 mm = 4.3 µL;2.00 mm = 6.8 µL.)
A40680.5 / 1.25 / 2 mm path, 1/4’’ connections, stainless steel, max. flow 10000, max. pressure 200 bar(Cell volumes for adjustable cells are: 0.50 mm = 1.7 µL; 1.25 mm = 4.3 µL;2.00 mm = 6.8 µL.)
A40670.5 / 1.25 / 2 mm path, 1/8’’ connections, PEEK, max. flow 1000, max. pressure 100 bar(Cell volumes for adjustable cells are: 0.50 mm = 1.7 µL; 1.25 mm = 4.3 µL;2.00 mm = 6.8 µL.)
A40690.5 mm path, 1/16’’ connections, stainless steel, max. flow 250, max. pressure 200 bar
A40950.5 mm path, 1/16’’ connections, PEEK, max. flow 250, max. pressure 100 bar
Analytical flow cells with double fiber optical connection
A407410 mm path, 1/16’’ connections, 10 µL, stainless steel, max. flow 20, max. pressure 300 bar
A40443 mm path, 1/16’’ connections, 2 µL, stainless steel, max. flow 50, max. pressure 300 bar
A40473 mm path, 1/16’’ connections, 2 µL, PEEK, max. flow 50, max. pressure 30 bar
A40773 mm path, 1/16’’ connections, 0.7 µL, PEEK, max. flow 10, max. pressure 30 bar
Preparative flow cells with double fiber optical connection
A40780.5 / 1.25 / 2 mm path, 1/8’’ connections, stainless steel, max. flow 1000, max. pressure 200 bar(Cell volumes for adjustable cells are: 0.50 mm = 1.7 µL; 1.25 mm = 4.3 µL;2.00 mm = 6.8 µL.)
A40790.5 / 1.25 / 2 mm path, 1/8’’ connections, PEEK, max. flow 1000, max. pressure 100 bar(Cell volumes for adjustable cells are: 0.50 mm = 1.7 µL; 1.25 mm = 4.3 µL;2.00 mm = 6.8 µL.)
A40810.5 / 1.25 / 2 mm path, 1/4’’ connections, stainless steel, max. flow 10000, max. pressure 200 bar(Cell volumes for adjustable cells are: 0.50 mm = 1.7 µL; 1.25 mm = 4.3 µL;2.00 mm = 6.8 µL.)
A40890.5 mm path, 1/16’’ connections, stainless steel, max. flow 250, max. pressure 200 bar
A40960.5 mm path, 1/16’’ connections, PEEK, max. flow 250, max. pressure 100 bar
U-Z ViewTM Micro Flow Cells (not available with fiber optics)
A40918 mm path, 1/16’’ connections, 0.140 µL, fused silica, max. flow 0.1, max. pressure 500 bar
A40448 mm path, 1/16’’ connections, 0.035 µL, fused silica, max. flow 0.01, max. pressure 500 bar
A40478 mm path, 1/16’’ connections, 0.003 µL, fused silica, max. flow 0.001, max. pressure 500 bar
CE Cell (Capillary Electrophoresis) (not available with fiber optics)
A40971 mm path, 1/16’’ connections, stainless steel
Spares and Accessories
A0895RS232 cable for serial PC-interface
A4071-1Deuterium lamp (35W)
A4072Tungsten-Halogen lamp
A4073Tungsten-Halogen lamp with base (required for first time installation)
A0911Fiber-optic connector, length 400mm
A0742Fiber-optic connector, length 750mm
A0740Fiber-optic connectors, length 750mm, pack of 2 items
A0743Fiber-optic connector (individual length to be specified with order)
A0857Extension Kit for coupling of two fiber-optic connectors
A4126Test cell, holmium oxide filter for detectors without fiber-optics
A4128Test cell, holmium oxide filter for detectors with fiber-optics
A14471 lens, 1 seal for analytical flow cells
A14481 lens, 1 seal for preparative flow cells
A14491 lens, 1 seal for flow cells using fiber optics
A1131Repair kit for analytical flow cells, 10mm
A1475Repair kit for analytical flow cells, 3mm
A1132Repair kit for preparative flow cells
Top of Page | Home PageCopyright © 2002-dato by flowspek ag
www.flowspek.ch | info@flowspek.chEfringerstrasse 32, CH-4057 Basel