Smartline HPLC Multi-Wavelength UV Detector 2550

Specifications

Ordering Information

Print Version

Documentation

Overview

 
Smartline Fast Scanning Multi-Wavelength HPLC Detector 2550

The Smartline HPLC Detector 2550 is a programmable rapid scanning detector for HPLC and, using new high speed scanning technology, can record multiple chromatograms at different wavelengths..
 
Fast data acquisition
The very high data rate of 80 Hz is suitable for fast chromatography applications.
 
Multiple Wavelengths
Up to 4 wavelengths can be measured simultaneously in real time on four freely-programmable detector channels.
 
GLP Functions
The Smartline HPLC Detector 2550 provides GLP functions such as: detailed reports, displaying the total hours of lamp operation, total number of lamp ignitions, and more.
 
Large Selection of Flow Cells
A large range of flow cells, from nano-HPLC cells for flowrates above 100 nL/minute to preparative cells for flowrates up to 10000 ml/minute, offers maximum flexibility and permits use of this detector for practically all HPLC applications.
 
Service Friendly
The entire optical unit slides out of the detector for easy exchange of lamps etc. The housing does not need to be removed thus making system servicing fast and easy.
 
Compact
The HPLC Detector 2550 has been designed to fit directly into the Smartline instrument family as part of a system tower. The modular design of the detector means that it can also be used as a completely separate HPLC module and its small size allows it to be installed practically anywhere.

 

Specifications

Top
 

Detector design

Fast scanning monochromator

Wavelength range

190 - 900 nm depending on lamp type

Wavelength accuracy

Better than ± 1 nm

Wavelength verification

Auto-calibration with deuterium spectral lines, verification with holmium oxide filter

Bandwidth

< 5 nm

Light source

Deuterium lamp as standard, optional tungsten-halogen lamp and dual lamps

Drift

= 0.5 x 10-4 AU/h, ASTM E1657-98

Noise

= 0.5 x 10-5 AU, ASTM E1657-98

Linearity

> 3 AU

Integrator output

Two times 0 - 5 V, 20 bit

Data acquisition

Analogue via Integrator output

Display

LCD, 2 x 24 characters

Remote control

Remote via RS-232 interface, LAN, analogue inputs for autozero, start program and lamp off, analogue outputs for error conditions

Local control

Touchpad

GLP

Recording of total running time and number of lamp ignitions.

Features

Programmable in Stand-alone mode, 20 programs

Dimensions

226 x 135 x 410 mm (W x H x D)

Weight

6 kg

All specifications may be subject to change for technical reasons.

 

 
Ordering Information
 

Top

A5190

Smartline UV Detector 2550 without flow cell, with accessories for operation without fiber-optics

Analytical Flow Cells

A4061

10 mm path, 1/16’’ connections, 10 µL, stainless steel, max. flow 20, max. pressure 300 bar

A4042

3 mm path, 1/16’’ connections, 2 µL, stainless steel, max. flow 50, max. pressure 300 bar

A4045

3 mm path, 1/16’’ connections, 2 µL, PEEK, max. flow 50, max. pressure 30 bar

Preparative Flow Cells

A4066

0.5 / 1.25 / 2 mm path, 1/8’’ connections, stainless steel, max. flow 1000, max. pressure 200 bar
(Cell volumes for adjustable cells are: 0.50 mm = 1.7 µL; 1.25 mm = 4.3 µL;2.00 mm = 6.8 µL.)

A4068

0.5 / 1.25 / 2 mm path, 1/4’’ connections, stainless steel, max. flow 10000, max. pressure 200 bar
(Cell volumes for adjustable cells are: 0.50 mm = 1.7 µL; 1.25 mm = 4.3 µL;2.00 mm = 6.8 µL.)

A4067

0.5 / 1.25 / 2 mm path, 1/8’’ connections, PEEK, max. flow 1000, max. pressure 100 bar
(Cell volumes for adjustable cells are: 0.50 mm = 1.7 µL; 1.25 mm = 4.3 µL;2.00 mm = 6.8 µL.)

A4069

0.5 mm path, 1/16’’ connections, stainless steel, max. flow 250, max. pressure 200 bar

A4095

0.5 mm path, 1/16’’ connections, PEEK, max. flow 250, max. pressure 100 bar

Analytical flow cells with double fiber optical connection

A4074

10 mm path, 1/16’’ connections, 10 µL, stainless steel, max. flow 20, max. pressure 300 bar

A4044

3 mm path, 1/16’’ connections, 2 µL, stainless steel, max. flow 50, max. pressure 300 bar

A4047

3 mm path, 1/16’’ connections, 2 µL, PEEK, max. flow 50, max. pressure 30 bar

A4077

3 mm path, 1/16’’ connections, 0.7 µL, PEEK, max. flow 10, max. pressure 30 bar

Preparative flow cells with double fiber optical connection

A4078

0.5 / 1.25 / 2 mm path, 1/8’’ connections, stainless steel, max. flow 1000, max. pressure 200 bar
(Cell volumes for adjustable cells are: 0.50 mm = 1.7 µL; 1.25 mm = 4.3 µL;2.00 mm = 6.8 µL.)

A4079

0.5 / 1.25 / 2 mm path, 1/8’’ connections, PEEK, max. flow 1000, max. pressure 100 bar
(Cell volumes for adjustable cells are: 0.50 mm = 1.7 µL; 1.25 mm = 4.3 µL;2.00 mm = 6.8 µL.)

A4081

0.5 / 1.25 / 2 mm path, 1/4’’ connections, stainless steel, max. flow 10000, max. pressure 200 bar
(Cell volumes for adjustable cells are: 0.50 mm = 1.7 µL; 1.25 mm = 4.3 µL;2.00 mm = 6.8 µL.)

A4089

0.5 mm path, 1/16’’ connections, stainless steel, max. flow 250, max. pressure 200 bar

A4096

0.5 mm path, 1/16’’ connections, PEEK, max. flow 250, max. pressure 100 bar

Spares and Accessories

A0895

RS232 cable for serial PC-interface

A1447

1 lens, 1 seal for analytical flow cells

A1448

1 lens, 1 seal for preparative flow cells

A1131

Repair kit for analytical flow cells, 10mm

A1475

Repair kit for analytical flow cells, 3mm

A1132

Repair kit for preparative flow cells

 

Top of Page | Home Page

© 2002-dato by flowspek ag, Efringerstrasse 32, CH-4057 Basel